Shear Behavior of Steel Fiber Reinforced Prestressed Concrete Beams

Muhammad Ahmad, Muhammad Mazhar Saleem, Muhammad Azhar Saleem, Ali Ahmed, Safeer Abbas

Abstract


Prestressed concrete girders are the main superstructure elements in many bridge structures. Shear failures in these girders are undesirable due to brittle failure and little warning time. To prevent shear controlled brittle failure, it is normal practice to increase the amount of transverse reinforcement in flexural members. However, past studies have revealed that even higher transverse reinforcement ratios (i.e. > 4%) may not be able to eliminate shear failure in some cases. Moreover, the increased reinforcement makes it more difficult to place and consolidate the concrete. This research program aimed to investigate the feasibility of replacing traditional shear reinforcement in prestressed concrete beams with steel fibers. A total of 14 rectangular and 8 I-shaped prestressed concrete beams were investigated after subjecting them to two-point loading test. The beams were casted with steel fiber ratios ranging from 0.75% to 2.00%. Experimental results revealed that the inclusion of steel fibers in concrete mix improved the shear strength of rectangular and I shaped prestressed beams. It was observed that on adding 1% fibers, the shear strength of I-beams enhanced by 23%. Moreover, in some cases, the addition of steel fibers also caused the shear failure mode to shift to flexural failure mode without traditional shear reinforcement. Furthermore, the cracking behavior and ultimate strength were also improved.  However, at high fiber dosages, balling of the fibers was observed and the load capacity decreased compared to beams with lower fiber contents.


Full Text:

PDF

References


Dhonde H, Mo Y, Hsu T. (2006). Fiber reinforcement in prestressed concrete beams. Report 0-4819, Texas Department of Transportation, 1-4.

Dhonde, H. (2006). Steel fibers and self-consolidating concrete in prestressed concrete beams.PhD. Dissertation, Department of Civil and EnvironmentalEngineering, University of Houston, TX.

Alabama Department of Transportation (ADOT)Research report.(1994). Cracks in precast prestressed bulb tee girders on structures no. I-565-45-11 A. and B. in I-565 in Huntsville, Alabama.

Marshall T, Mattock H. (1962). Control of horizontal cracking in the ends of pretensioned release. PCI Journal, 7 (5), 56-74.

Cucchiara C, Mendola L, Papia M. (2004). Effectiveness of stirrups and steel fibres as shear reinforcement. Cement and Concrete Composites, 26 (7), 777-786.

Kwak K, Eberhar O, Kim S, Kim J. (2002). Shear strength of steel fiber-reinforced concrete beams without stirrups. ACI Structural Journal, 99 (4), 530-538.

Narayanan, R., Darwish, I. Y. S. (1987). Use of Steel Fibers as Shear Reinforcement.ACI Structural Journal, 216-227.

Swamy N, Baha M. (1979). Influence of fiber reinforcement on the dowel resistance to shear. ACI Journal Proceeding, 76 (2), 327-355.

Lim H, Oh H. (1999). Experimental and theoretical investigation on the shear of steel fiber reinforced concrete beams. Engineering Structures, 21 (10), 937-944.

Dhonde H, Tadepalli P, Mo Y, Hsu T. (2008). Shear behaviour of prestressed beams with steel fiber self compacting concrete. The 14th World Conference on Earthquake Engineering, 1-8.

Narayanan R, Darwish S. (1987). Shear in prestressed concrete beams containing steel fibers. International Journal of Cement Composites and Lightweight Concrete, 9 (2), 81-90.

Cho, S.H., and Kim, Y.I.L. (2003). Effects of Steel Fibers on Short Beams Loaded in Shear. ACI Structural Journal, 100(6), 765-774.

Zeeshan, R. (2014), “Replacement of Traditional Shear Reinforcement with Steel Fibers in Prestressed Concrete Beams.MSc. Thesis, University of Engineering and Technology Lahore, 30-47.

Huang, L., Xu, L., Chi, Y., & Xu, H. (2015). Experimental investigation on the seismic performance of steelpolypropylene hybrid fiber reinforced concrete columns. Construction and Building Materials, 87, 16-27.

Tadepalli, P.R., Dhonde, H.B., Mo, Y.L. and Hsu, T.C. (2015). Shear Strength of Prestressed Steel Fiber Concrete I-Beams. International Journal of Concrete Structures and Materials, 9(3), 267-281.

Padmarajaiah K, Ramaswamy A. (2001). Behavior of fiber reinforced prestressed and reinforced high strength concrete beams subjected to shear. ACI Structural Journal, 98 (5), 752-761.

Wahab S, Al-Kadhimi G. (2000). Effect of SFRC on shear strength of prestressed concrete beams. Magazine of Concrete Research, 52 (1), 43-51.

Kazemi S, Lubell A. (2012). Influence of specimen size and fiber content on mechanical properties of ultra-high performance fiber-reinforced concrete. ACI Materials Journal,109(6), 675-684.

Orgass M, Klug Y. (2004). Fiber-reinforced ultra-high strength concretes.Proceedings of the International Symposium on Ultra High Performance Concrete, Kassel, Germany, 637-648.

ACI 318-14. (2014). Building Code Requirements for Structural Concrete,” American Concrete Institute, Farmington Hills, Michigan.

Khuntia, M. (1999). “Shear Strength of Normal and High Strength Fiber Reinforced Concrete Beams without Stirrups.ACI Structural Journal,96(2), 282–290.






Copyright (c) 2020 Pakistan Journal of Engineering and Applied Sciences

Powered By KICS