Analysis of Transient Flow and Heat Transfer in a Vertical Inverted U– Tube Steam Generator

N. A. Shahid, M. O. Ahmad, M. Mushtaq, S. Nazir

Abstract


A mathematical model of a vertical inverted U–tube steam generator (UTSG) is used to analyze the transient flow and heat transfer in it. To simulate the transients, the mathematical model is discretised in time and space coordinates. For the solution of this one dimensional heat problem, a finite differences numerical simulation technique is employed in order to find the temperature distribution of primary and secondary fluids. An optimum boiling length of the tube is also obtained. For further analysis, the temperature distribution profiles of secondary and primary fluids are drawn at specified intervals of time.

Full Text:

PDF

References


B. Noel and R. Deruaz, “Reflux Condensation with Nitrogen in Steam Generator U–Tubes Analysis of Bethsy Test 72.c Using CATHARE Code”, 3rd Intl. Symposium on Multiphase Flow and Heat Transfer, Xi’an, China (1994).

W.H. Strohmayer, Dynamic Modeling of Vertical U– Tube Steam Generators for Operational Safety Systems, P. 4–19, Ph.D Thesis (1982).

N.A. Shahid, N.A. Shah, “Analysis of Temperature Distribution in a Power Plant”, Research Journal of University of Engineering and Technology, Lahore (Pakistan), Volume 7 July–December (1993).

N.A. Shahid, M.O. Ahmad, S. Nazir and M. Mushtaq, “Analysis of Mathematical Model of a U–Tube Steam Generator Under Steady State Conditions”, Pakistan Journal of Scientific Research Lahore, Vol. 60 No. 1–2 (March, 2008).

N.A. Shahid, M.O. Ahmad, M. Mushtaq, and S. Nazir “Numerical Simulation of Heat Transfer in a Vertical Inverted U–Tube Steam Generator”, Pakistan Journal of Engineering and Applied Sciences, University of Engineering & Technology, Lahore, Vol. 4 January 2009.






Copyright (c) 2016 N. A. Shahid